Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Article in English | LILACS, BBO | ID: biblio-1346670

ABSTRACT

ABSTRACT Objective: To propose a classification of patients by occlusal condition and its apparent validation. Material and Methods: This cross-sectional analytical study was divided into two phases. In the first, a trained examiner divided the patients into four groups according to the proposed classification of this design: Type 1 patient - completely dentate individuals; Type 2 - partially edentulous individuals with occlusal stability; Type 3 - partially edentulous individuals with no occlusal stability; Type 4 - completely edentulous individuals. In this phase, 122 patients were analyzed with an instrument developed for this experiment. Results: All patients in the sample of this research were classified in some division of the proposed instrument. In the second phase, the apparent validation of the classification was conducted by three judges, who obtained an excellent agreement with the allocation of patients in one of the types according to the indication of the first examiner (Kappa = 85%). Conclusion: It is evident that the classification presents reliability, ease of visualization, good conditions for interprofessional communication, and it can be used in dental clinical practice to assist in the study and integrated planning of clinical cases.


Subject(s)
Humans , Orthodontics , Oral Health , Classification/methods , Dental Occlusion , Mandible/surgery , Patient Care Planning , Brazil/epidemiology , Cross-Sectional Studies/methods , Data Interpretation, Statistical
2.
J. appl. oral sci ; 23(1): 9-13, Jan-Feb/2015. graf
Article in English | LILACS, BBO | ID: lil-741585

ABSTRACT

A current goal of dental implant research is the development of titanium (Ti) surfaces to improve osseointegration. Plasma nitriding treatments generate surfaces that favor osteoblast differentiation, a key event to the process of osteogenesis. Based on this, it is possible to hypothesize that plasma-nitrided Ti implants may positively impact osseointegration. Objective The aim of this study was to evaluate the in vivo bone response to Ti surfaces modified by plasma-nitriding treatments. Material and Methods Surface treatments consisted of 20% N2 and 80% H2, 450°C and 1.5 mbar during 1 h for planar and 3 h for hollow cathode. Untreated surface was used as control. Ten implants of each surface were placed into rabbit tibiae and 6 weeks post-implantation they were harvested for histological and histomorphometric analyses. Results Bone formation was observed in contact with all implants without statistically significant differences among the evaluated surfaces in terms of bone-to-implant contact, bone area between threads, and bone area within the mirror area. Conclusion Our results indicate that plasma nitriding treatments generate Ti implants that induce similar bone response to the untreated ones. Thus, as these treatments improve the physico-chemical properties of Ti without affecting its biocompatibility, they could be combined with modifications that favor bone formation in order to develop new implant surfaces. .


Subject(s)
Animals , Male , Rabbits , Osseointegration/drug effects , Plasma Gases/therapeutic use , Tibia/drug effects , Tibia/surgery , Titanium/therapeutic use , Biocompatible Materials , Cell Differentiation/drug effects , Osteoblasts/drug effects , Osteogenesis/drug effects , Plasma Gases/chemistry , Reproducibility of Results , Surface Properties , Time Factors , Titanium/chemistry , Treatment Outcome
3.
Braz. dent. sci ; 15(2): 19-26, 2012. tab, ilus
Article in English | LILACS, BBO | ID: lil-681467

ABSTRACT

Over the last decade, a considerable development of new technologies to the modification of dental implants has been observed contributing to reduce the healing process and their use in areas with low bone density. Among the new techniques, plasma nitriding has showed excellent results. In this study, a superficial modification of commercial pure titanium (Degree II), by using two different plasma treatments (planar and hollow cathode nitriding) was accomplished aiming at an optimization of the surface for biomedical applications. An evaluation of the chemical composition in all samples was carried out, in addition to a study of their roughness and texture. Then, stem cells were deposited onto these surfaces and a comparison among their properties and their biological behavior was accomplished. The results showed that the nitriding techniques produced significant changes in the superficial texture of the Ti samples. The roughness test presented better results in samples nitrided by hollow cathode technique. Statistically significant differences were found in the cell proliferation of samples nitrided by hollow cathode nitriding when compared to samples without treatment. The used techniques were, therefore, effective and directly influenced the characteristics of the titanium surface and consequently, the stem cell behavior.


Nos últimos anos tem-se observado um grande crescimento em tecnologias para modificação de superfícies de implantes dentais visando reduzir o tempo de espera pela cicatrização, assim como possibilitar seu uso com sucesso em áreas de baixa densidade óssea. Dentre esses métodos de modificação, a nitretação por plasma tem apresentado ótimos resultados. No presente trabalho, estudou-se superfícies de titânio comercialmente puro (Grau II) modificadas através de dois tratamentos por plasma diferentes (nitretação planar e nitretação em cátodo oco), com o objetivo de obter uma otimização da superfície para aplicações biomédicas. Uma avaliação da composição química e um estudo da rugosidade e textura destas amostras foram realizados. Em seguida, depositou-se células-tronco sobre essas superfícies e uma comparação entre as novas propriedades obtidas e a proliferação celular foi feita. Os resultados mostraram que a nitretação por plasma produziu mudanças significativas na textura superficial das amostras de titânio. A rugosidade foi superior nas amostras nitretadas em cátodo oco. Encontrou-se diferença estatisticamente significante na proliferação celular das amostras nitretadas em cátodo oco quando comparadas com as amostras sem tratamento. Essas técnicas de modificação são, portanto, efetivas e possuem influência direta nas características da superfície e no comportamento de células-tronco.


Subject(s)
Dental Implants , Plasma , Titanium
4.
Ciênc. odontol. bras ; 11(2): 49-57, abr.-jun. 2008. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-524131

ABSTRACT

Para a confecção de coroas metalocerâmicas, uma série de etapas devem ser realizadas. A mudança nesses passos pode ocasionar alterações tanto na liga metálica como na porcelana e como conseqüência, na adesão entre elas. Um fator que deve ser levado em consideração, consiste em analisar o efeito das refusões, uma vez que nos laboratórios protéticos torna-se comum a prática do seu reaproveitamento. Tal fato pode ocasionar perda qualitativa e quantitativa dos elementos de liga e como conseqüência, diferença em suas propriedades, sendo um grande indicativo de falhas em certas coroas. O objetivo deste trabalho foi analisar o efeito do número de refusões sobre a microestrutura, porosidade e dureza dessa liga, contribuindo, desta forma, para uma melhoria dos trabalhos protéticos na realização das coroas metalocerâmicas. Deste modo, coroas de ligas refundidas em 1 e 2 vezes, foram comparadas com aquelas apenas fundidas em dois laboratórios de prótese de Natal-RN. As microestruturas foram observadas por microscopia óptica. Utilizando-se o programa de análise de imagem, Image Pro-Plus, avaliou-se a porosidade existente nessas amostras. A amostra fundida apresentou regiões com porosidade máxima de 9% no laboratório 1 e 11% no laboratório 2, enquanto que as amostras das ligas refundidas e refundidas 2 vezes apresentaram porosidades até 14% e 86% respectivamente no laboratório 1 e 12% e 70% no laboratório 2. Com relação à microdureza, os resultados indicaram que, na medida em que se aumenta o número de refusões, a dureza diminui para ambos os laboratórios.


Subject(s)
Crowns , Dental Alloys
SELECTION OF CITATIONS
SEARCH DETAIL